Model: ZBF16S80AYCC4P9-A6
Series: 4-16S
Cell type: Li-ion / PoLife04
Rated current: 60A / 100A / 120A / 160A (According to Capacity Board)
Communication interface: RS485 / CAN
Others: 4G+GPS/Led Indication Board/Heating function/64MB storage memory /clock function - 【Series】:LoT Series
Introduction
This BMS adopted the lower consumption with higher precision chip, which fully protection the charging and discharging of a single lithim battery packed. It applied the intelligient software to evaluate the accurately SOC. Meanwhile, it provide the 4G platform and GPS tracking system for remote monitoring. The battery packed can transmit the SOC data via RS485 or CAN communication protocol. The mainboard can match with difference capacity board according to the user requested for achieved the higher cost performance. At the same time, it can add 4G+GPS tracking module, LED indicator, heating module, bluetooth module and display module etc for satisfied any case requirement.
Application
Battery charging cabinet / Solar Power System / Uninterrupted Power System
Advantage:
Safety: Fully Battery protection management, ensure the battery working under the safety condition
Storage: 64MB memory for record the battery historical data.
Accurately: Calculate the accurately SOC via the intelligent software
Convenience: Monitoring the battery performance remotely via 4G or bluetooth function.
Features:
(1)Setting the protection figure flexibly via the software
(2)Transmitted the battery data and updated the software online through RS485 or CAN communication protocal
(3)4 way temperature monitoring function, ensure the battery does not appear the overheating conditions
(4)Voltage balancing function extend the battery life
(5)Led indicator on time display the battery state (Option)
(6)64MB memory for record the battery historical data
(7)Provided the accurately time
(8)Support key switch function
(9)Heating function ensure the battery packed used in lower temperature area. (Option)
(10)4G and bluetooth function achieve the remote monitoring purpose. (Option)
Voltage Protection
Overcharge voltage protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Overcharge protection voltage(Vov) |
0 |
3650 |
5000 |
±30 |
mV |
Overcharge protection delay time(tov) |
0 |
2000 |
600000 |
±500 |
mS |
Overcharge protection recovery voltage(Vovr) |
0 |
3550 |
5000 |
±50 |
mV |
Overcharge protection recovery delay time(tovr) |
0 |
2000 |
600000 |
±500 |
mS |
Overdischarge voltage protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Overdischarge protection voltage(Vov) |
0 |
2600 |
5000 |
±30 |
mV |
Overdischarge protection delay time(tov) |
0 |
2000 |
600000 |
±500 |
mS |
Overdischarge protection recovery voltage(Vovr) |
0 |
2800 |
5000 |
±50 |
mV |
Ovedisrcharge protection recovery delay time(tovr) |
0 |
2000 |
600000 |
±500 |
mS |
Current Protection
First Layer Discharge Overcurrent Protection
Configuration
Item |
Capacity Board |
Min. |
Default |
Max. |
Tolerance |
Unit |
First Layer Discharge Overcurrent Proection |
A6-YMOS-TOLLA-V21-Diff Port |
0 |
80 |
80 |
±2 |
A |
A6-YMOS-TOLLA-V21-Same Port |
0 |
110 |
110 |
±2 |
A |
|
A6-YMOS-263-V21-Diff Port |
0 |
80 |
80 |
±2 |
A |
|
A6-YMOS-263-V21-Same Port |
0 |
50 |
50 |
±2 |
A |
|
First Layer discharge overcurrent protection delay time |
0 |
10000 |
600000 |
±20 |
mS |
|
First Layer discharge overcurrent protection recovery delay time |
0 |
1000 |
600000 |
±10 |
mS |
Second Layer Discharge Overcurrent Protection
Configuration
Item |
Capacity Board |
Min |
Default |
Max |
Tolerance |
Unit |
Second Layer Discharge Overcurrent Protection |
A6-YMOS-TOLLA-V21-Diff Port |
0 |
120 |
120 |
±2 |
A |
A6-YMOS-TOLLA-V21-Same Port |
0 |
160 |
160 |
±2 |
A |
|
A6-YMOS-263-V21-Diff Port |
0 |
100 |
100 |
±2 |
A |
|
A6-YMOS-263-V21-Same Port |
0 |
60 |
60 |
±2 |
A |
|
Second Layer discharge overcurrent protection delay time |
0 |
100 |
600000 |
±20 |
mS |
|
Second Layer discharge overcurrent protection recovery delay time |
0 |
1000 |
600000 |
±10 |
mS |
First Layer Charging Overcurrent Protection
Configuration
Item |
Capacity Board |
Min. |
Default |
Max. |
Tolerance |
Unit |
First Layer Charging Overcurrent Protection |
A6-YMOS-TOLLA-V21-Diff Port |
0 |
50 |
50 |
±2 |
A |
A6-YMOS-TOLLA-V21-Same Port |
0 |
110 |
110 |
±2 |
A |
|
A6-YMOS-263-V21-Diff Port |
0 |
40 |
40 |
±2 |
A |
|
A6-YMOS-263-V21-Same Port |
0 |
50 |
50 |
±2 |
A |
|
First Layer Charging Overcurrent Protection Delay Time |
0 |
10000 |
600000 |
±20 |
mS |
|
First Layer Charging Overcurrent Protection Recovery Delay Time |
0 |
1000 |
600000 |
±10 |
mS |
Second Layer Charging Overcurrent Protection
Configuration
Item |
Capacity Board |
Min. |
Default |
Max. |
Tolerance |
Unit |
Secondary Layer Charging Overcurrent Protection |
A6-YMOS-TOLLA-V21-Diff Port |
0 |
60 |
60 |
±2 |
A |
A6-YMOS-TOLLA-V21-Same Port |
0 |
160 |
160 |
±2 |
A |
|
A6-YMOS-263-V21-Diff Port |
0 |
50 |
50 |
±2 |
A |
|
A6-YMOS-263-V21-Same Port |
0 |
60 |
60 |
±2 |
A |
|
Secondary Layer Charging Overcurrent Protection Delay Time |
0 |
100 |
600000 |
±20 |
mS |
|
Secondary Layer Charging Overcurrent Protection Recovery Delay Time |
0 |
1000 |
600000 |
±10 |
mS |
Short Circuit Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Short Circuit Voltage |
0.1 |
/ |
0.4 |
/ |
mV |
Short Circuit Delay Time |
Hardware |
/ |
/ |
/ |
mS |
Short Circuit Recovery Time |
0 |
/ |
600000 |
±100 |
mS |
Balancing Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Balancing Protection Voltage |
0 |
3400 |
5000 |
±50 |
mV |
Wasting Current once started |
50 |
/ |
100 |
/ |
mA |
Temperature Protection
Discharging temperature protection
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Discharging over temperature protection degree |
-40 |
65 |
86 |
±3 |
ͦC |
Discharging over temperature protection recovery degree |
-40 |
60 |
86 |
±3 |
ͦC |
Discharging under temperature protection degree |
-40 |
-15 |
86 |
±3 |
ͦC |
Discharging under temperature protection recovery degree |
-10 |
-15 |
86 |
±3 |
ͦC |
MOSFET OVERHEAT PROTECTION
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
|
Mosfet overheat protection degree |
-40 |
70 |
86 |
±3 |
ͦC |
|
Mosfet overheat recovery degree |
-40 |
60 |
86 |
±3 |
ͦC |
|
Mosfet overheat protection delay time |
0 |
3000 |
600000 |
±100 |
mS |
Mosfet failure protection
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Judgment current |
/ |
1 |
/ |
/ |
A |
Judgment delay time |
/ |
30 |
/ |
/ |
S |
Power Consumption
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Working Mode: RS485 / CAN |
0 |
35 |
35 |
/ |
mA |
Working Mode: RS485 / CAN without output signal but the current is larger than wake up setting |
0 |
35 |
35 |
/ |
mA |
Sleeping Mode: RS485 / CAN witout output signal but the current is lower than wake up setting |
0 |
300 |
300 |
/ |
uA |
Hibernate Mode: Battery voltage is lower than setting figure |
0 |
30 |
30 |
/ |
uA |
Warning Setting
Cell Voltage warning
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
The battery cell overvoltage warning figure |
0 |
3500 |
5000 |
±50 |
mV |
The battery cell undervoltage warning figure |
0 |
2700 |
5000 |
±50 |
mA |