- Storge Energy Series BMS
- 【Brief】:
Model: ZBF16S100AYCC4C9-E1-V01
Series: 4-16S
Cell type: Li-ion / LifeP04
Rated Current: 100A
Communication Protocol: 2 X RS485 / 1 X CAN / 1 X UR
Limited Charging Current: 10A
Others: Built in 64MB memory / Clock / 6 digital DIP switch / Heating connector
- 【Series】:LoT Series
Introduction
This BMS is available for 16S or below comunication lithium battery. It offer the fully protection such as overvoltage, undervoltage, overcurrent, higher temperature, lower temperature and short circuit etc for the battery packed. Provide the accurate SOC data during charging and discharging processing, Meanwhile, it can on time display and setting the protection and warning figure via intelligent software. The built in memory can store the operating battery histical data.
Application
AIO based station/ Solar Power System/ Mirco Grid Power System
Advantage
(1) Safety: Fully battery protection ensure the battery operated under safety condition.
(2) Convenience: Monitoring the battery state remotely via the intelligent software
(3)Volume: Battery Historical data following the battery charging and discharging performance
(4)Life: Voltage balancing function prolong the cell life
(5)Flexibility: Suitable for the Li-ion or LiFePO4
Features
(1)Setting the protection figure flexibly via the intelligent software
(2)Fully battery protection/warning function
(3)Transmit the battery data and updated the setting figure through RS485 or CAN communication protocol
(4)4 way temperature monitoring function, ensure the battery does not appear the overheating conditions
(5)Voltage balancing function prolong the battery life
(6)Battery heating connector allowed the battery using in lower temperature environment. (Option)
(7)LED indicator showed the battery operation and fault state
(8)With 10A limited charging function
(9)Built in 64MB memory for recorded the battery historical data
(10)With clock function
(11)Support key switch function
(12)Suited for difference type of battery cell
Voltage Protection
Overcharge voltage protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Overcharge protection voltage(Vov) |
0 |
3650 |
5000 |
±30 |
mV |
Overcharge protection delay time(tov) |
0 |
2000 |
600000 |
±500 |
mS |
Overcharge protection recovery voltage(Vovr) |
0 |
3550 |
5000 |
±50 |
mV |
Overcharge protection recovery delay time(tovr) |
0 |
2000 |
600000 |
±500 |
mS |
Overdischarge voltage protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Overdischarge protection voltage(Vov) |
0 |
2600 |
5000 |
±30 |
mV |
Overdischarge protection delay time(tov) |
0 |
2000 |
600000 |
±500 |
mS |
Overdischarge protection recovery voltage(Vovr) |
0 |
2800 |
5000 |
±50 |
mV |
Ovedisrcharge protection recovery delay time(tovr) |
0 |
2000 |
600000 |
±500 |
mS |
Current Protection
First Layer Discharge Overcurrent Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
First Layer Discharge Overcurrent Proection |
0 |
80 |
80 |
±2 |
A |
First Layer discharge overcurrent protection delay time |
0 |
10000 |
600000 |
±20 |
mS |
First Layer discharge overcurrent protection recovery delay time |
0 |
1000 |
600000 |
±10 |
mS |
Second Layer Discharge Overcurrent Protection
Configuration
Item |
Min |
Default |
Max |
Tolerance |
Unit |
Second Layer Discharge Overcurrent Protection |
0 |
120 |
120 |
±2 |
A |
Second Layer discharge overcurrent protection delay time |
0 |
100 |
600000 |
±20 |
mS |
Second Layer discharge overcurrent protection recovery delay time |
0 |
1000 |
600000 |
±10 |
mS |
First Layer Charging Overcurrent Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
First Layer Charging Overcurrent Protection |
0 |
50 |
50 |
±2 |
A |
First Layer Charging Overcurrent Protection Delay Time |
0 |
10000 |
600000 |
±20 |
mS |
First Layer Charging Overcurrent Protection Recovery Delay Time |
0 |
1000 |
600000 |
±10 |
mS |
Second Layer Charging Overcurrent Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Second Layer Charging Overcurrent Protection |
0 |
60 |
60 |
±2 |
A |
Second Layer Charging Overcurrent Protection Delay Time |
0 |
100 |
600000 |
±20 |
mS |
Second Layer Charging Overcurrent Protection Recovery Delay Time |
0 |
1000 |
600000 |
±10 |
mS |
Short Circuit Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Short Circuit Voltage |
0.1 |
/ |
0.4 |
/ |
mV |
Short Circuit Delay Time |
Hardware |
/ |
/ |
/ |
mS |
Short Circuit Recovery Time |
0 |
/ |
600000 |
±100 |
mS |
The external AC breaker is necessary for the short circuit protection |
Balancing Protection
Configuration
Item |
Min. |
Default |
Max. |
Tolerance |
Unit |
Balancing Protection Voltage |
0 |
3400 |
5000 |
±50 |
mV |
Wasting Current once started |
50 |
/ |
100 |
/ |
mA |
Temperature Protection
Discharging temperature protection
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Discharging over temperature protection degree |
-40 |
65 |
86 |
±3 |
ͦC |
Discharging over temperature protection recovery degree |
-40 |
60 |
86 |
±3 |
ͦC |
Discharging under temperature protection degree |
-40 |
-15 |
86 |
±3 |
ͦC |
Discharging under temperature protection recovery degree |
-40 |
-10 |
c86 |
±3 |
ͦC |
Mosfet overheat protection
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
|
Mosfet overheat protection degree |
-40 |
70 |
86 |
±3 |
ͦC |
|
Mosfet overheat recovery degree |
-40 |
60 |
86 |
±3 |
ͦC |
|
Mosfet overheat protection delay time |
0 |
3000 |
600000 |
±100 |
mS |
Mosfet failure protection
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Judgment current |
/ |
1 |
/ |
/ |
A |
Judgment delay time |
/ |
30 |
/ |
/ |
S |
Power Consumption
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Working Mode: RS485 / CAN |
0 |
35 |
35 |
/ |
mA |
Working Mode: RS485 / CAN without output signal but the current is larger than wake up setting |
0 |
35 |
35 |
/ |
mA |
Sleeping Mode: RS485 / CAN witout output signal but the current is lower than wake up setting |
0 |
300 |
300 |
/ |
uA |
Hibernate Mode: Battery voltage is lower than setting figure |
0 |
30 |
30 |
/ |
uA |
Warning Setting
Cell Voltage warning
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
The battery cell overvoltage warning figure |
0 |
3500 |
5000 |
±50 |
mV |
The battery cell undervoltage warning figure |
0 |
2700 |
5000 |
±50 |
mA |
Cell temperature warning under discharging condition
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Discharging over temperature warning degree |
-40 |
55 |
86 |
±3 |
ͦC |
Discharging over temperature warning recovery degree |
-40 |
50 |
86 |
±3 |
ͦC |
Discharging under temperature warning degree |
-40 |
0 |
86 |
±3 |
ͦC |
Discharging under temperature warning recovery degree |
-40 |
5 |
86 |
±3 |
ͦC |
Cell temperature warning under charging condition
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
Discharging over temperature warning degree |
-40 |
45 |
86 |
±3 |
ͦC |
Discharging over temperature warning recovery degree |
-40 |
40 |
86 |
±3 |
ͦC |
Discharging under temperature warning degree |
-40 |
0 |
86 |
±3 |
ͦC |
Discharging under temperature warning recovery degree |
-40 |
5 |
86 |
±3 |
ͦC |
Mosfet Overheat warning
Configuration
Item |
Min. |
Default |
Max |
Tolerance |
Unit |
|
Mosfet overheat warning degree |
-40 |
65 |
86 |
±3 |
ͦC |
|
Mosfet overheat warning recovery degree |
-40 |
60 |
86 |
±3 |
ͦC |